4 research outputs found

    Portable infrared imaging for longitudinal limb volume monitoring in patients with lymphatic filariasis

    Get PDF
    BACKGROUND: The Global Programme to Eliminate Lymphatic Filariasis (LF) emphasizes hygiene, exercise, and other measures to reduce morbidity and disability related to LF. We recently reported that a portable, three-dimensional, infrared imaging system (3DIS) provides accurate limb volume measurements in patients with filarial lymphedema. To assess the practical utility of repeated 3DIS measurements for longitudinal lymphedema management, we examined intraday and day-to-day leg volume changes in adults with filarial lymphedema in southern Sri Lanka. METHODOLOGY AND PRINCIPAL FINDINGS: We assessed 41 participants with lower extremity lymphedema (stages 1-6) in their homes in the mornings (6:00-9:00 AM) and afternoons (2:00-6:00 PM) of three days within one calendar week. Two examiners performed replicate 3DIS volume measurements at each visit. Median coefficient of variation among replicate volume measurements was 1.7% (IQR 1.1% - 2.3%) for left legs and 2.2% (IQR 1.6% - 2.8%) for right legs. Median intraday volume increase was 3.0%. Range among daily volume measurements tended to be lower for afternoon measurements (median 2.25%, IQR 1.4%- 5.4%) than for morning measurements (median 3.0%, IQR 1.4% - 8.4%). CONCLUSIONS AND SIGNIFICANCE: Limb volume measurements by 3DIS are accurate and reproducible, and this technique is feasible for use in patients\u27 homes. We have developed practical suggestions for optimal outcomes with 3DIS. Duplicate measurements should be performed and repeat assessments should be done at approximately the same time of day to minimize bias. Duplicate measures that vary by more than 8% should prompt review of scanning technique with a repeat measurement. With proper training and attention to technique, 3DIS can be a valuable tool for healthcare workers who work with lymphedema patients

    Validation of an In-House ELISA Method in the Diagnosis of Cutaneous Leishmaniasis Caused by Leishmania donovani in Hambantota District, Sri Lanka

    No full text
    Clinical diagnosis has become a challenge amidst a surge of cutaneous leishmaniasis in Southern Sri Lanka. The routine diagnostic method, slit-skin smear (SSS), has variable sensitivity, leading to undiagnosed cases. Improved diagnostics are urgently needed. We assessed a new in-house ELISA method for its diagnostic capabilities against ITS-1 nested PCR (gold standard—Gs). A cohort of 190 clinical CL cases was examined by SSS microscopy, anti-rKRP42 IgG ELISA (serum- and urine-based), and rK39-Immunochromatographic strip test. Validation was done using non-endemic sera, and cutoffs were developed using the receiver operating curve. The sensitivity of SSS for case detection was 77.9% (authors) and 76.3% (technicians). ELISA vs. Gs demonstrated sensitivity (Sn) = 94.4%; specificity (Sp) = 50.0%; positive predictive value (PPV) = 97.1%; negative predictive value (NPV) = 33.3%; Kappa agreement (Kp) = 0.39/p < 0.01. Comparison of the combination method (SSS by technicians and ELISA) vs. Gs showed: Sn = 98.9%; Sp = 30.0; PPV = 96.2; NPV 60.0%; Kp = 0.378/p < 0.01. All methods performed better compared to SSS (29.4%) where the clinical diagnosis was doubtful (PCR = 94.15%; serum ELISA = 88.2%; combination = 94.1%; p < 0.01 for all). High serum anti-rKRP42 titers were seen in those with multiple lesions. Anti-rKRP42 urine ELISA was suboptimal as a diagnostic test. A 9% rate of positivity was seen for rk39-ICT, and positives recorded high anti-rKRP42 titers. The diagnostic accuracy can be increased above the level of the Gs by combining SSS and ELISA. Advanced studies are required to understand the association between rk39-ICT positivity and high anti-rKRP42 titers

    Development of a Highly Sensitive Nested PCR and Its Application for the Diagnosis of Cutaneous Leishmaniasis in Sri Lanka

    No full text
    The recent surge in cutaneous leishmaniasis (CL) in Sri Lanka has rendered clinical diagnosis difficult; thus, laboratory confirmation is indispensable. A modified (two novel inner primers to detect CL caused by Leishmania donovani) nested Internal Transcribed Spacer-1 (ITS1) PCR-Restriction Fragment Length Polymorphism (RFLP) method was developed and tested. The sensitivity of the modified nested PCR was tested using serial dilutions (103 to 10−2) of the DNA extract of a cultured L. donovani DD8 strain. Patients (n = 194) from Southern Sri Lanka were examined clinically, microscopically (Slit Skin Smear-SSS) and using the modified nested PCR. The modified nested PCR detected 2.55 fg of parasite DNA compared to ITS1 PCR (25 fg) and detected more cases than SSS (94.3% vs. 77.3%; p < 0.01). The RFLP pattern was L. donovani in all cases. The modified nested PCR performed well in clinically doubtful lesions (95% by PCR vs. 60% by SSS; p < 0.01), ulcerated nodules (91% vs. 71.8%; p < 0.01) and plaques (100% vs. 66.7%; p < 0.01). SSS demonstrated sensitivity (80.9%), specificity (81.8%), PPV (98.7%) and NPV (20.5%) against modified PCR. Low parasite loads and atypical lesions can be diagnosed by the proposed method with higher accuracy
    corecore